   * overvoltage   * overvoltage
     * Incorrect Absorption setpoints.  AGM is commonly Absorped at <= 14.4v while FLA is commonly Absorped higher (at 14.7v-14.8v).  Check your manufacturer's recommendation and do not exceed it.  Overvoltage causes irrepairable damage by outgassing, and AGM cannot be topped off again like FLA.     * Incorrect Absorption setpoints.  AGM is commonly Absorped at <= 14.4v while FLA is commonly Absorped higher (at 14.7v-14.8v).  Check your manufacturer's recommendation and do not exceed it.  Overvoltage causes irrepairable damage by outgassing, and AGM cannot be topped off again like FLA.
-    * Equalization. **Do not equalize AGM**!((lifeline excepted)).    +    * Equalization. **Do not equalize AGM**!((lifeline excepted)).   
 +  * Low current charging.  Cheap AGM require [[electrical:12v:battery_capacity|C/5]] current minimum in Bulk, and expensive ones require C/3.
   * the lead-acid list above   * the lead-acid list above
  