electrical:batterycide [2020/07/21 12:42]
frater_secessus [murdering flooded lead-acid]
electrical:batterycide [2020/07/21 12:43]
frater_secessus [murdering AGM]
Line 20: Line 20:
  
 ===== murdering AGM ===== ===== murdering AGM =====
-AGM have benefits but are easier to murder.+[[opinion:frater_secessus:the_case_for_agm|AGM have benefits]] but are easier to murder.
  
 +  * the lead-acid list above((except the part about low water levels))
   * overvoltage   * overvoltage
     * Incorrect Absorption setpoints.  AGM is commonly Absorped at <= 14.4v while FLA is commonly Absorped higher (at 14.7v-14.8v).  Check your manufacturer's recommendation and do not exceed it.  Overvoltage causes irrepairable damage by outgassing, and AGM cannot be topped off again like FLA.     * Incorrect Absorption setpoints.  AGM is commonly Absorped at <= 14.4v while FLA is commonly Absorped higher (at 14.7v-14.8v).  Check your manufacturer's recommendation and do not exceed it.  Overvoltage causes irrepairable damage by outgassing, and AGM cannot be topped off again like FLA.
     * Equalization. **Do not equalize AGM**!((lifeline excepted)).       * Equalization. **Do not equalize AGM**!((lifeline excepted)).  
   * Low current charging.  Cheap AGM require [[electrical:12v:battery_capacity|C/5]] current minimum in Bulk, and expensive ones require C/3.   * Low current charging.  Cheap AGM require [[electrical:12v:battery_capacity|C/5]] current minimum in Bulk, and expensive ones require C/3.
-  * the lead-acid list above+
  
  
electrical/batterycide.txt ยท Last modified: 2023/08/24 22:52 by princess_fluffypants