   * leaving them at [[electrical:12v:psoc|partial state of charge]], resulting in //irreversible// sulfation((AKA "hard" sulfation.  The battery undergoes "soft" sulfation and desulfation during normal charging/discharging.)) Fully charging each day is optimal.  Fully charging //almost// every day is acceptable.   * leaving them at [[electrical:12v:psoc|partial state of charge]], resulting in //irreversible// sulfation((AKA "hard" sulfation.  The battery undergoes "soft" sulfation and desulfation during normal charging/discharging.)) Fully charging each day is optimal.  Fully charging //almost// every day is acceptable.
   * not charging at [[electrical:solar:charge_controller_setpoints|manufacturer-recommended Absorption voltage]] (Vabs) to reverse normally-occurring ("soft") sulfation. This is most commonly caused by [[electrical:12v:alternator|isolator-only]] charging since the house bank is being charged at ((or slightly below)) alternator voltage. \\ Less commonly, [[electrical:solar|Solar]]-only charging can cause this problem if the [[electrical:solar:sizing|battery capacity is too great for the solar output]].((http://support.rollsbattery.com/support/solutions/articles/5964-battery-sulfation))   * not charging at [[electrical:solar:charge_controller_setpoints|manufacturer-recommended Absorption voltage]] (Vabs) to reverse normally-occurring ("soft") sulfation. This is most commonly caused by [[electrical:12v:alternator|isolator-only]] charging since the house bank is being charged at ((or slightly below)) alternator voltage. \\ Less commonly, [[electrical:solar|Solar]]-only charging can cause this problem if the [[electrical:solar:sizing|battery capacity is too great for the solar output]].((http://support.rollsbattery.com/support/solutions/articles/5964-battery-sulfation))
-  * not holding Vabs for sufficient duration so that absorption current drops to manufacturer-recommended levels. [[electrical:generator#charging_batteries|Generator-]] or  [[electrical:12v:b2b|DC-DC charging]] can cause this unless the charger runs the necessary number of hours it takes to complete Absorption.  +  * not holding Vabs for [[electrical:severe_battery_use#increasing_effective_absorption_duration|sufficient duration]] so that absorption current drops to manufacturer-recommended levels. [[electrical:generator#charging_batteries|Generator-]] or  [[electrical:12v:b2b|DC-DC charging]] can cause this unless the charger runs the necessary number of hours it takes to complete Absorption.  
   * discharging too deeply.  Maximum discharge is typically limited to 50% [[electrical:depth_of_discharge|depth of discharge]].   * discharging too deeply.  Maximum discharge is typically limited to 50% [[electrical:depth_of_discharge|depth of discharge]].
   * allowing the cells to get low on distilled water.  Check them 1x/month or so until you learn their personality.   * allowing the cells to get low on distilled water.  Check them 1x/month or so until you learn their personality.
  
 ===== murdering AGM ===== ===== murdering AGM =====
-AGM have benefits but are easier to murder.+[[opinion:frater_secessus:the_case_for_agm|AGM have benefits]] but are easier to murder.
  
 +  * the lead-acid list above((except the part about low water levels))
   * overvoltage   * overvoltage
     * Incorrect Absorption setpoints.  AGM is commonly Absorped at <= 14.4v while FLA is commonly Absorped higher (at 14.7v-14.8v).  Check your manufacturer's recommendation and do not exceed it.  Overvoltage causes irrepairable damage by outgassing, and AGM cannot be topped off again like FLA.     * Incorrect Absorption setpoints.  AGM is commonly Absorped at <= 14.4v while FLA is commonly Absorped higher (at 14.7v-14.8v).  Check your manufacturer's recommendation and do not exceed it.  Overvoltage causes irrepairable damage by outgassing, and AGM cannot be topped off again like FLA.
     * Equalization. **Do not equalize AGM**!((lifeline excepted)).       * Equalization. **Do not equalize AGM**!((lifeline excepted)).  
   * Low current charging.  Cheap AGM require [[electrical:12v:battery_capacity|C/5]] current minimum in Bulk, and expensive ones require C/3.   * Low current charging.  Cheap AGM require [[electrical:12v:battery_capacity|C/5]] current minimum in Bulk, and expensive ones require C/3.
-  * the lead-acid list above+
  
  