electrical:depth_of_discharge [2020/06/10 13:00]
frater_secessus [SoC by voltage]
electrical:depth_of_discharge [2020/06/10 13:01]
frater_secessus [effect of SoC on battery life]
Line 8: Line 8:
 ===== effect of SoC on battery life ===== ===== effect of SoC on battery life =====
  
-How deeply one discharges lead-chemistry batteries will have a **direct effect on how long the battery bank will last**.((Banks are typically replaced when they have lost 20% of their capacity))+How deeply one regularly discharges lead-chemistry batteries will have a **direct effect on how long the battery bank will last**.((Banks are typically replaced when they have lost 20% of their capacity))
  
  
Line 64: Line 64:
   * temperature of the battery   * temperature of the battery
   * SG chart from the battery manufacuturer   * SG chart from the battery manufacuturer
-  * [[https://amzn.to/3dOHGEU|battery SG tester (//hydrometer//)]]+  * [[https://amzn.to/3dOHGEU|battery SG tester (hydrometer)]]
  
  