electrical:depth_of_discharge [2023/08/17 21:28]
frater_secessus [soft and firm charging]
electrical:depth_of_discharge [2023/08/17 21:28]
frater_secessus [soft and firm charging]
Line 36: Line 36:
 So while we can say with confidence that a 100Ah Li battery charged at 20A to 14.0v will be ~100% SoC, the same battery charged to 14.0v at 80A might only be at 75% SoC.  And it **could get damagingly overcharged** if charged to 14.0v very gently at something like 5A.((the BMS cannot detect this scenario)) So while we can say with confidence that a 100Ah Li battery charged at 20A to 14.0v will be ~100% SoC, the same battery charged to 14.0v at 80A might only be at 75% SoC.  And it **could get damagingly overcharged** if charged to 14.0v very gently at something like 5A.((the BMS cannot detect this scenario))
  
-The amp counter will probably help here during charging although even it can be thrown off. +The amp counter will probably help here during charging although even it can be thrown off;  see the battery monitor article for more on this
  
  
electrical/depth_of_discharge.txt ยท Last modified: 2023/08/17 21:36 by frater_secessus