electrical:inverter [2023/07/25 10:58]
frater_secessus [inverter chargers]
electrical:inverter [2023/11/22 14:34]
frater_secessus [Inverters]
Line 11: Line 11:
  
 AC-only items will require an inverter.  [[electrical:12v:wallwart|Devices that run off a "wall wart" adapter]] almost never require an inverter.   AC-only items will require an inverter.  [[electrical:12v:wallwart|Devices that run off a "wall wart" adapter]] almost never require an inverter.  
 +
 +===== efficiency =====
 +
 +Inverting from DC to your local shore power spec will necessarily incur losses.  These might be 10-30%, depending on the inverter, the inverter's efficiency spec, etc.  In the absence of hard information you might use 20% losses as a rule of thumb.  This means it will require 20% more power to run your load than the rating spec.
 +
 +50w * 0.8 efficiency = 60w demanded from the system
  
  
Line 69: Line 75:
 {{ https://m.media-amazon.com/images/I/61wb7PGYPNL._AC_UL320_.jpg?150}} \\ {{ https://m.media-amazon.com/images/I/61wb7PGYPNL._AC_UL320_.jpg?150}} \\
  
-//Inverter/chargers// are most often found on rigs that are on shore power much of the time.  +//Inverter/chargers// are most often found on rigs that are on shore power much of the time and run heavy AC loads 
  
  
Line 77: Line 83:
   - some can bond shore and battery power to support heavy 120vac loads   - some can bond shore and battery power to support heavy 120vac loads
   - charge battery banks like a [[electrical:converter|converter]]   - charge battery banks like a [[electrical:converter|converter]]
 +  - some also handle solar charging
  
 They tend to be [[https://amzn.to/2KMcImw|expensive]], some over $1000. They tend to be [[https://amzn.to/2KMcImw|expensive]], some over $1000.
  
 +Note:  the Victron Multiplus line has outputs for maintaining the starter battery:
 +
 +
 +>> The main DC terminal can supply the full output current. The second output, intended for charging  starter battery, is limited to 4A and has a slightly lower output voltage.((https://www.victronenergy.com/upload/documents/Manual-MultiPlus-3k-120V-(firmware-xxxx4xx)-EN.pdf))
 ===== Sizing your inverter ===== ===== Sizing your inverter =====
  
electrical/inverter.txt ยท Last modified: 2024/04/20 22:18 by frater_secessus