Line 30: Line 30:
  
  
-  * if duration setpoint is maxxed then **set Vfloat == Vabs**.  Absorption duration will effectively be "until the sun goes down".  +  * if duration setpoint is maxxed then [[electrical:12v:eternal_absorption|set Vfloat == Vabs]].  Absorption duration will effectively be "until the sun goes down".  
   * **charge at a lower current** (charging minimum).  While [[opinion:frater_secessus:charging_faster|overall charging will take about the same amount of time]], Bulk's share of that time will increase and [[electrical:12v:charging#absorption|Absorption will take somewhat less time]].   * **charge at a lower current** (charging minimum).  While [[opinion:frater_secessus:charging_faster|overall charging will take about the same amount of time]], Bulk's share of that time will increase and [[electrical:12v:charging#absorption|Absorption will take somewhat less time]].
   * **charge at a higher voltage** (Vabs), this will decrease Absorption duration.  Keep a close watch on water levels for flooded batts, and also mind the max allowable voltage for AGM/Gel.    * **charge at a higher voltage** (Vabs), this will decrease Absorption duration.  Keep a close watch on water levels for flooded batts, and also mind the max allowable voltage for AGM/Gel. 