====== Solar charge controller setpoints ====== | ====== Solar charge controller setpoints ====== | ||
- | Controller behavior is guided by // | + | [[electrical: |
===== charging setpoints ===== | ===== charging setpoints ===== | ||
- | Most charging-related setpoints are // | ||
- | * Float voltage (Vfloat) - the voltage the battery bank is held at during [[electrical: | + | |
- | * Absorption voltage (Vabs) - the voltage the battery bank is held at during [[electrical: | + | |
- | * Absorption duration - the amount of time Vabs will be held until dropping to Vfloat. | + | |
- | * Absorption termination | + | |
- | * Absorption restart - voltage (or duration) at which Absorption stage after failing to maintain Vfloat | + | |
===== load setpoints ===== | ===== load setpoints ===== | ||
+ | Only present on controllers with LOAD outputs. | ||
+ | |||
+ | * **Low voltage disconnect (Vlvd)** - voltage at which the controller turns off loads to prevent excessive battery discharge. | ||
+ | * **Low voltage reconnect (Vlvr)** - the setpoint at which the load is turned back on after recovering from Vlvd cutoff. | ||