===== non-setpoint settings ===== | ===== non-setpoint settings ===== |
| |
* **Maximum charge rate:** While maximum charge rates normally are immaterial to solar charging((lead batteries accept what they want rather than taking what they are given)), Trojan specfies a maximum of [[electrical:12v:battery_capacity|C]]/5, or 1/5th of the battery's capacity in Ah. | * **Maximum charge rate:** While maximum charge rates normally are immaterial to solar charging((lead batteries accept what they want rather than taking what they are given)), Trojan specfies a maximum of [[electrical:12v:battery_capacity|C]]/5, or 1/5th of the battery's capacity in Ah for this flooded example. C/3 is a common max for AGM. Lithium max charge is typically stated as C/2 for maximum life. |
* **Minimum charge rate:** not stated in our example, but typical minimum charging values are ~C/10 for lead chemistries. | * **Minimum charge rate:** not stated in our example, but typical minimum charging values are ~C/10 for flooded lead batteries, and ~C/5 for AGM. Lithium does not have a practical minimum rate so is not damaged by weak charging. |
| |
| |