-"MPPT is required for series"​ is shorthand for "when [[electrical:​12v:​electrical_notation|Vmp]] greatly exceeds battery bank voltages PWM output is hamstrung and MPPT advantage is overwhelming."​((In our PWM backup scenario we are not concerned with //maximum// power, only getting //some// power from the panels until we can replace the dead MPPT.))+"MPPT is required for series"​ is shorthand for "when [[electrical:​12v:​electrical_notation|Vmp]] greatly exceeds battery bank voltages PWM output is hamstrung and MPPT advantage is overwhelming."​((In our PWM backup scenario we are not concerned with //maximum// power, only getting //some// power from the panels until we can replace the dead MPPT.)) ​ For example, running 2 12v panels in series to charge a 12v battery bank. 
   ​   ​
 The flipside to this is "when Vmp is close to battery voltage then MPPT advantage is thinnest and PWM may actually make more power."​ For more on this edge scenario, see [[electrical:​solar:​output#​panel_temperature|temperature derating]]. The flipside to this is "when Vmp is close to battery voltage then MPPT advantage is thinnest and PWM may actually make more power."​ For more on this edge scenario, see [[electrical:​solar:​output#​panel_temperature|temperature derating]].
electrical/solar/faq_mppt_series.txt ยท Last modified: 2020/01/09 16:40 by frater_secessus