* Victron: Vpanel >= Vbatt + 5v to start MPPT, Vbatt + 1v thereafter.((https://www.victronenergy.com/upload/documents/Manual-BlueSolar-charge-controller-MPPT-75-10-75-15--100-15-EN-NL-FR-DE-ES-SE-ul.pdf)) | * Victron: Vpanel >= Vbatt + 5v to start MPPT, Vbatt + 1v thereafter.((https://www.victronenergy.com/upload/documents/Manual-BlueSolar-charge-controller-MPPT-75-10-75-15--100-15-EN-NL-FR-DE-ES-SE-ul.pdf)) |
* Genasun (nominal 12 systems): 15-18v for constant power supplies((https://genasun.com/support/faq/)), <= 27v for PV.((https://www.bruceschwab.com/wp-content/uploads/sites/86/2018/01/GV-10_Manual-2017.pdf)) | * Genasun (nominal 12 systems): 15-18v for constant power supplies((https://genasun.com/support/faq/)), <= 27v for PV.((https://www.bruceschwab.com/wp-content/uploads/sites/86/2018/01/GV-10_Manual-2017.pdf)) |
| * SNA (grid tied): Vpanel = desired output * 1.4142((https://www.researchgate.net/profile/Aalok_Bhatt/post/How_to_select_MPPT_Range_of_Solar_Inverter/attachment/59d624496cda7b8083a1f834/AS%3A377507284045824%401467016158673/download/SMA+Datasheet.pdf)) |
* generic rule of thumb: Vpanel >= maxiumum Vbatt + 30% FIXME | * generic rule of thumb: Vpanel >= maxiumum Vbatt + 30% FIXME |
* generic rule of thumb: Vpanel = maximum Vbat * | * generic rule of thumb: Vpanel = maximum Vbat * |