Line 5: Line 5:
 In practice, actual loads may be heavier in the daytime (as when working with power tools) or at night (as when watching movies or running a forced-air furnace).   In practice, actual loads may be heavier in the daytime (as when working with power tools) or at night (as when watching movies or running a forced-air furnace).  
  
-Due to the nature of battery charging there are better times and worse times to run non-essential loads.  If done attentively (or automatically) **one can run electrical loads that do not affect the battery's  +If loads are applied attentively (or automatically!) **one can run electrical loads that [[electrical:solar:offthepanel|do not affect]] the battery bank's  
-[[electrical:depth_of_discharge|State of Charge]]** at all.  This is especially true for Lead-Acid chemistries that do not take much current in [[electrical:12v:charging|Float or late Absorption stages]].+[[electrical:depth_of_discharge|State of Charge]]** at all.  Additionally, consuming loads at the right time can also increase the health and longevity of lead batteries.((by keeping them at 100% SoC more of the time))
  
 ===== how much surplus current is there? ===== ===== how much surplus current is there? =====
Line 16: Line 16:
 There will generally be more "surplus" power available when using MPPT charge controllers v. PWM,((http://forum.solar-electric.com/discussion/comment/372165#Comment_372165))((http://forum.solar-electric.com/discussion/comment/250746#Comment_250746)) though the difference is less dramatic during periods one would run opportunity loads (see [[electrical:solar:nonessential#when_to_run_opportunity_loads|below]]).  Siphoning off power can actually **help PWM controllers run cooler** by reducing the ON-OFF switching activity that generates heat. There will generally be more "surplus" power available when using MPPT charge controllers v. PWM,((http://forum.solar-electric.com/discussion/comment/372165#Comment_372165))((http://forum.solar-electric.com/discussion/comment/250746#Comment_250746)) though the difference is less dramatic during periods one would run opportunity loads (see [[electrical:solar:nonessential#when_to_run_opportunity_loads|below]]).  Siphoning off power can actually **help PWM controllers run cooler** by reducing the ON-OFF switching activity that generates heat.
  
 +[[electrical:solar:overpaneling|Overpaneled]] systems have even more excess power available. 
 ===== when to run opportunity loads ===== ===== when to run opportunity loads =====
  