**The best time to run non-essential loads is when there is surplus current** over what battery charging needs. This means **during Float, or after current has started dropping off in Absorption**. For [[electrical:12v:deep_cycle_battery#lithium_chemistries|LiFePO4]] there is excess power any time after the bank has reached the intended charge state. | **The best time to run non-essential loads is when there is surplus current** over what battery charging needs. This means **during Float, or after current has started dropping off in Absorption**. For [[electrical:12v:deep_cycle_battery#lithium_chemistries|LiFePO4]] there is excess power any time after the bank has reached the intended charge state. |
| |
Opportunity loads should not be applied during [[electrical:12v:charging|Bulk stage]] since Bulk, by definition, means the battery is taking all the available current.((assuming no charging limit has been configured in the [[electrical:solar:charge_controller|charge controller]])) | Opportunity loads should not be applied during [[electrical:12v:charging|Bulk stage]] since Bulk, by definition, means the battery is taking all the available current.((assuming no charging limit has been configured in the [[electrical:solar:charge_controller|charge controller]]))\ |
| |
| **PWM controllers** will make [[electrical:solar:pwm_tweaking|most power during Absorption]] when voltage is highest. Wait until current demand falls low enough that your loads will not affect Absorption. |
| |
| |
electrical/solar/nonessential.txt · Last modified: 2023/10/18 19:08 by frater_secessus