electrical:solar:nonessential [2023/10/18 19:04] frater_secessus [when to run opportunity loads] |
electrical:solar:nonessential [2023/10/18 19:05] frater_secessus [when to run opportunity loads] |
There is a little more wiggle room with [[electrical:12v:deep_cycle_battery#lithium_chemistries|LiFePO4]]; the loads can be run with no net negative effect on a Lithium system when | There is a little more wiggle room with [[electrical:12v:deep_cycle_battery#lithium_chemistries|LiFePO4]]; the loads can be run with no net negative effect on a Lithium system when |
| |
* the bank has reached the intended charge state | * the bank has reached the intended charge state; or |
* or any time the bank can be //projected// to reach the intended charge state by sundown while carrying the extra loads. In effect, lithium allows you to "borrow" against future charging without penalty.. Exception: Lithium setups with PWM [[electrical:solar:charge_controller|solar charge controllers]] will make [[electrical:solar:pwm_tweaking|most power]] when bank voltage is highest. So waiting for Float or Absorption to run opportunity loads will mean the solar can make more Wh per day. | * any time the bank can be //projected// to reach the intended charge state by sundown while carrying the extra loads. In effect, lithium allows you to "borrow" against future charging without penalty.. Exception: Lithium setups with PWM [[electrical:solar:charge_controller|solar charge controllers]] will make [[electrical:solar:pwm_tweaking|most power]] when bank voltage is highest. So waiting for Float or Absorption to run opportunity loads will mean the solar can make more Wh per day. |
| |
| |
electrical/solar/nonessential.txt · Last modified: 2023/10/18 19:08 by frater_secessus