So a [[camping:snowbirding|snowbird]] who "chases 60" will be losing ~10% of panel output during the warmest part of the day. Snowbirds chasing 70 will be losing ~13% of panel output. | So a [[camping:snowbirding|snowbird]] who "chases 60" will be losing ~10% of panel output during the warmest part of the day. Snowbirds chasing 70 will be losing ~13% of panel output. |
| |
| Note: sub-freezing temperatures can push Voc/Vmp above their rated values. If you will use solar in sub-freezing conditions leave plenty Voc headroom in your solar charge controller spec. |
| |
Note: that [[hvac:insulation#heat_from_solar_panels|radiated heat from the underside of panels can raise temperatures inside the camper]]. | Note: that [[hvac:insulation#heat_from_solar_panels|radiated heat from the underside of panels can raise temperatures inside the camper]]. |