electrical:solar:output [2020/05/17 16:45]
frater_secessus [panel tilt]
electrical:solar:output [2020/05/20 08:30] (current)
frater_secessus [charge controller type]
Line 10: Line 10:
 ===== charge controller type ===== ===== charge controller type =====
  
-Due to their design, [[electrical:​solar:​charge_controller#​pwm|PWM]] and [[electrical:​solar:​charge_controller#​shunt|shunt]] charge controllers will very rarely allow the panel to run at max output for given conditions. ​ The lower the battery voltage (Vbatt) the lower the panel voltage (Vpanel), therefore the lower the power output.((Vpanel * ~Imp = P))+Due to their design, [[electrical:​solar:​charge_controller#​pwm|PWM]] and [[electrical:​solar:​charge_controller#​shunt|shunt]] charge controllers will very rarely allow the panel to run at max output for given conditions. ​ The lower the battery voltage (Vbatt) the lower the panel voltage (Vpanel), therefore the lower the power output.((Vpanel * ~Imp = P))  The output can be increased somewhat by [[electrical:​solar:​pwm_tweaking|tweaking battery voltages higher]].
  
 [[electrical:​solar:​charge_controller#​mppt|MPPT]] controllers can run the panel at max output when needed, but are much more expensive. ​ [[electrical:​solar:​charge_controller#​mppt|MPPT]] controllers can run the panel at max output when needed, but are much more expensive. ​
electrical/solar/output.txt ยท Last modified: 2020/05/20 08:30 by frater_secessus