electrical:solar:overpaneling

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
electrical:solar:overpaneling [2018/07/20 16:45]
frater_secessus [MPPT and heat]
electrical:solar:overpaneling [2018/12/06 07:47]
frater_secessus [Overpaneling] common meaning
Line 4: Line 4:
  
   * [[#vs._charge_controller|overpaneled charge controller]] - battery bank and charge controller are evenly matched;  panel nominal or actual output is  more than the controller's rating.   * [[#vs._charge_controller|overpaneled charge controller]] - battery bank and charge controller are evenly matched;  panel nominal or actual output is  more than the controller's rating.
-  * [[#vs._battery_bank|overpaneled battery bank]] - solar panels and charge controller are evenly matched; both are oversized compared to battery bank.+  * [[#vs._battery_bank|overpaneled battery bank]] - solar panels and charge controller are evenly matched; both are oversized compared to battery bank.  This is the most common meaning.
    
  
Line 39: Line 39:
   -  when there is very little load being used   -  when there is very little load being used
  
-This occurs because the PPT controller moves Vpanel toward Voc to reduce current when less is needed but battery voltage is high, as in late Absorption .  This occurs because the greater the voltage conversion the more heat is produced.  For this reason, and perhaps counterintuitively, adding some load to the system in Absorption can drop PV voltage (and therefore CC temps) to lower levels.((http://forum.solar-electric.com/discussion/comment/256896#Comment_256896))+This occurs because the PPT controller moves Vpanel toward Voc to reduce current when less is needed but battery voltage is high, as in late Absorption.  For this reason adding some load to the system in Absorption can //reduce// PV voltage (and therefore CC temps) to lower levels.((http://forum.solar-electric.com/discussion/comment/256896#Comment_256896))
  
  