The overpaneled system's power output bell curve is //shifted upwards// and cut off by the controller when it reaches its limits. This is known as clipping, trimming, or clamping due to the "flat top" appearance of the overpaneled output curve. | The overpaneled system's power output bell curve is //shifted upwards// and cut off by the controller when it reaches its limits. This is known as clipping, trimming, or clamping due to the "flat top" appearance of the overpaneled output curve. |
| |
With modest overpaneling the clipping is relatively minor. Victron notes that: | With appropriate overpaneling the clipping is relatively minor. Victron notes that: |
| |
>> Generally total energy harvested from a 130% panel oversizing results in less than 1% annual energy loss. -- [[https://www.victronenergy.com/blog/2014/03/28/matching-victron-energy-solar-modules-to-the-new-mppt-charge-regulators/source]] | >> Generally total energy harvested from a 130% panel oversizing results in less than 1% annual energy loss. -- [[https://www.victronenergy.com/blog/2014/03/28/matching-victron-energy-solar-modules-to-the-new-mppt-charge-regulators/|source]] |
| |
| |