Differences
This shows you the differences between two versions of the page.
Both sides previous revision
Previous revision
Next revision
|
Previous revision
Next revision
Both sides next revision
|
electrical:solar:panels [2022/05/24 11:19] frater_secessus [Specifications] |
electrical:solar:panels [2022/07/10 16:54] frater_secessus [Panel voltage] |
| |
| |
* **Nominal 12v panels** have 36 cells. They will generally have max power (Vmp) around 18v and open circuit (Voc) around 21v.((https://www.altestore.com/howto/solar-panels-pv-and-voltages-a98/)) These are commonly found on mobile and portable installations. | * **Nominal 12v panels** have 36 cells. They will generally have max power (Vmp) around 18v and open circuit (Voc) around 21v.((https://www.altestore.com/howto/solar-panels-pv-and-voltages-a98/)) These are commonly found on mobile and portable installations. \\ Note: there are some "12v" panels that actually have 40 cells.((nominal 13v?)) Example: [[https://amzn.to/3Pcrcsi|Renogy 200w "12v"]] panels, with Vmp of 22.6v and Voc 27v. The extra voltage //cannot be harvested by PWM// so MPPT is effectively required with these. |
* **Nominal 20v panels** have 60 cells. They will generally have max power (Vmp) around 30v and open circuit (Voc) around 36v.((https://www.altestore.com/howto/solar-panels-pv-and-voltages-a98/)) These are commonly found in residential rooftop installations. | * **Nominal 20v panels** have 60 cells. They will generally have max power (Vmp) around 30v and open circuit (Voc) around 36v.((https://www.altestore.com/howto/solar-panels-pv-and-voltages-a98/)) These are commonly found in residential rooftop installations. |
* **Nominal 24v panels** have 72 cells. They will generally have max power (Vmp) around 36v and open circuit (Voc) around 42v.((https://www.altestore.com/howto/solar-panels-pv-and-voltages-a98/)) These are commonly found in commercial or residential ground level installations. Due to internal construction (actually 2 36-cell segments in parallel)((https://youtu.be/ofo1HQyGG8s?t=1m22s)) they can be more resistant to partial shading. | * **Nominal 24v panels** have 72 cells. They will generally have max power (Vmp) around 36v and open circuit (Voc) around 42v.((https://www.altestore.com/howto/solar-panels-pv-and-voltages-a98/)) These are commonly found in commercial or residential ground level installations. Due to internal construction (actually 2 36-cell segments in parallel)((https://youtu.be/ofo1HQyGG8s?t=1m22s)) they can be more resistant to partial shading. |
| |
Panel voltage((more precisely, the relationship between panel voltage and battery voltage)) is an important factor when [[electrical:solar:charge_controller#how_to_choose|selecting a solar charge controller]]. | Panel voltage((more precisely, the relationship between panel voltage and battery voltage)) is an important factor when [[electrical:solar:charge_controller#how_to_choose|selecting a solar charge controller]]. |
| |
| |
===== Efficiency ===== | ===== Efficiency ===== |
| |