electrical:solar:pwm_tweaking [2019/05/09 18:09]
frater_secessus [battery: maintain a higher state of charge]
electrical:solar:pwm_tweaking [2019/07/17 05:20] (current)
frater_secessus [set Vabs and Vfloat relatively high]
Line 46: Line 46:
  
 Since the panels make more power at higher voltages((up to Vmp)) cranking up Vabs and Vfloat to higher-but-still-sane levels will result in more power being harvested. ​ Since the panels make more power at higher voltages((up to Vmp)) cranking up Vabs and Vfloat to higher-but-still-sane levels will result in more power being harvested. ​
 +
 +Using the above panel as an example, Vabs of 14.7v will yield 3.5% more power than a Vabs of 14.1v. ​ Vfloat of 13.8v will yield 4.5% more power than a Vfloat of 13.2v. \\
 +Note:  consult the battery manufacturer'​s recommendations for the actual maximum voltages. ​ Controller presets often are set too low by the factory since they don't know what battery you will use it with. Better safe than sorry, say their lawyers. ​
 +
 ==== battery: maintain a higher state of charge ==== ==== battery: maintain a higher state of charge ====
  