electrical:solar:series_vs_parallel [2024/01/03 14:05] frater_secessus [TL;DR] |
electrical:solar:series_vs_parallel [2024/01/03 14:09] frater_secessus [TL;DR] |
| |
* With [[electrical:solar:charge_controller#mppt|MPPT]] solar charge controllers and 12v house battery bank there is often //little practical difference between parallel and series solar arrays//. | * With [[electrical:solar:charge_controller#mppt|MPPT]] solar charge controllers and 12v house battery bank there is often //little practical difference between parallel and series solar arrays//. |
* [[electrical:solar:charge_controller#pwm|PWM controllers]] run arrays of the same nominal voltage as their battery bank: 12v and 12v, 24v and 24v. | * [[electrical:solar:charge_controller#pwm|PWM controllers]] run arrays of the same nominal voltage as their battery bank: 12v and 12v, 24v and 24v. |
* A 24v array, for example, could be made of 24v panels in parallel or 12v panels in series. | * //generally speaking//, parallel panels will perform better in [[electrical:solar:shading|partial shade]] than series. [but don't shade your panels in the first place -- secessus] |
| * as with other [[electrical:12v:parallel_serial|series/parallel arrangements]], series increases voltage and parallel increases current. |
* series arrays can reduce capital costs in some circumstances | * series arrays can reduce capital costs in some circumstances |
* series/parallel arrangements are described with ''xPxS'' nomenclature: | * series/parallel arrangements are described with ''xPxS'' nomenclature: |
electrical/solar/series_vs_parallel.txt · Last modified: 2024/03/09 11:00 by frater_secessus