 ==== how it works ==== ==== how it works ====
  
-  - a simple [[electrical:solar:charge_controller#shunt_controller|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the significant gassing point+  - a simple [[electrical:solar:charge_controller#shunt|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the significant gassing point
   - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v)   - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v)
   - the controller's LOAD output //re//connects (LVR) at ~13.0v);  see discussion below   - the controller's LOAD output //re//connects (LVR) at ~13.0v);  see discussion below
-  - power is //only// taken from the controller's LOAD output;((or from a circuit control by a relay on the LOAD output)) this ensures the starter battery is never discharged below the intended setpoint+  - power is //only// taken from the controller's LOAD output;((or from a circuit control by a relay on the LOAD output)) this ensures the starter battery is never discharged below [[electrical:12v:lvd|the intended setpoint]]
  