electrical:solar:shallow_cycling
Differences
This shows you the differences between two versions of the page.
Both sides previous revision
Previous revision
Next revision
|
Previous revision
Next revision
Both sides next revision
|
electrical:solar:shallow_cycling [2018/06/16 20:51] frater_secessus [shallow-cycling] |
electrical:solar:shallow_cycling [2018/07/10 11:32] frater_secessus [how it works] |
==== how it works ==== | ==== how it works ==== |
| |
- a simple [[electrical:solar:charge_controller#shunt_controller|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the significant gassing point | - a simple [[electrical:solar:charge_controller#shunt|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the significant gassing point |
- the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v) | - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v) |
- the controller's LOAD output //re//connects (LVR) at ~13.0v); see discussion below | - the controller's LOAD output //re//connects (LVR) at ~13.0v); see discussion below |
- power is //only// taken from the controller's LOAD output;((or from a circuit control by a relay on the LOAD output)) this ensures the starter battery is never discharged below the intended setpoint | - power is //only// taken from the controller's LOAD output;((or from a circuit control by a relay on the LOAD output)) this ensures the starter battery is never discharged below [[electrical:12v:lvd|the intended setpoint]] |
| |
=== Low Voltage Reconnect (LVR) setpoint === | === Low Voltage Reconnect (LVR) setpoint === |
electrical/solar/shallow_cycling.txt ยท Last modified: 2023/04/08 13:41 by frater_secessus