User Tools

Site Tools


electrical:solar:shallow_cycling

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
electrical:solar:shallow_cycling [2018/06/16 20:54]
frater_secessus [how it works]
electrical:solar:shallow_cycling [2018/07/10 11:32]
frater_secessus [how it works]
Line 19: Line 19:
   - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v)   - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v)
   - the controller's LOAD output //re//connects (LVR) at ~13.0v);  see discussion below   - the controller's LOAD output //re//connects (LVR) at ~13.0v);  see discussion below
-  - power is //only// taken from the controller's LOAD output;((or from a circuit control by a relay on the LOAD output)) this ensures the starter battery is never discharged below the intended setpoint+  - power is //only// taken from the controller's LOAD output;((or from a circuit control by a relay on the LOAD output)) this ensures the starter battery is never discharged below [[electrical:12v:lvd|the intended setpoint]]
  
 === Low Voltage Reconnect (LVR) setpoint === === Low Voltage Reconnect (LVR) setpoint ===
electrical/solar/shallow_cycling.txt ยท Last modified: 2023/04/08 13:41 by frater_secessus