 ==== how it works ==== ==== how it works ====
  
-  - a simple [[electrical:solar:charge_controller#shunt|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the significant gassing point+  - a simple [[electrical:solar:charge_controller#shunt|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v, see notes [[electrical:solar:shallow_cycling#charging_voltages_and_starter_batteries|below]]) when charging, just below the significant gassing point
   - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v)   - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v)
   - the controller's LOAD output //re//connects (LVR) at ~13.0v);  see discussion below   - the controller's LOAD output //re//connects (LVR) at ~13.0v);  see discussion below
Line 105: Line 105:
   * 13.6v Float    * 13.6v Float 
  
-So a smart charger fitting that profile should be gentle enough on the battery.+So a charge controller with that configuration should be gentle enough on the battery.
  
  