====== Sizing a solar installation ====== | ====== Sizing a solar installation ====== |
| |
Sizing **residential off-grid solar configurations** is relatively easy: calculate power needs in the worst case scenario (December in a particular geographical area)((https://web.archive.org/web/20110906013732/http://www.solarpowerforum.net/forumVB/solar-energy/1793-basic-off-grid-solar-design.html)) and pay for it. | Sizing **residential off-grid solar configurations** is relatively easy: calculate power needs in the worst case scenario (December in a particular geographical area)((https://web.archive.org/web/20110906013732/http: |
| //www.solarpowerforum.net/forumVB/solar-energy/1793-basic-off-grid-solar-design.html)) and pay for it. |
| |
| Sizing **off-grid solar configurations for campers** has many more variables: |
| |
- worst case scenario [[electrical:12v:loads|loads]] (the max loads you will apply in any 24hr period((or at any given time, if you plan to run heavy loads))) | - worst case scenario [[electrical:12v:loads|loads]] (the max loads you will apply in any 24hr period((or at any given time, if you plan to run heavy loads))) |
| |
**Example:** You need 100AH x 1 day, so your bank will be 200AH cycled 50% each day. \\ | **Example:** You need 100AH x 1 day, so your bank will be 200AH cycled 50% each day. \\ |
**Example:** [[electrical:12v:lifepo4_batteries_thread|LiFePO4]] can be drained down to 80%-90% DoD so you would need only 110AH of rated capacity with that chemistry. 120AH if you are conservative. | **Example:** [[electrical:12v:deep_cycle_battery#lithium_chemistries|LiFePO4]] can be drained down to 80%-90% DoD so you would need only 110AH of rated capacity with that chemistry. 120AH if you are conservative. |
| |
| |
Solar power often works best when paired with another power source. This is because the first half and second half of [[electrical:12v:charging|smart charging]] have different time/power ramifications | Solar power often works best when paired with another power source. This is because the first half and second half of [[electrical:12v:charging|smart charging]] have different time/power ramifications |
| |
- **high current / short duration** during Bulk <-- [[electrical:generator|generators]], [[electrical:shore_power|shore power]] [[electrical:converter|converters]] and [[electrical:12v:alternator|alternator]] charging does this best | - **high current / short duration** during Bulk <-- [[electrical:generator|generator]], [[electrical:shore_power|shore power]] [[electrical:converter|converter]] and [[electrical:12v:alternator|alternator]] charging do this best |
- **low current / long duration** once Absorption gets underway, and during Float <-- solar does this best | - **low current / long duration** once Absorption gets underway, and during Float <-- solar does this best |
| |