       * Inversion from 24vdc to 110vac is more efficient than inversion from 12vdc.       * Inversion from 24vdc to 110vac is more efficient than inversion from 12vdc.
     * You have large, power-hungry appliances that can run natively off of 24v     * You have large, power-hungry appliances that can run natively off of 24v
-      * Some [[food:refrigeration|DC refrigerators]] can run off of both 12v or 24v, and are slightly more efficient when running off of 24v+      * Some [[food:refrigeration|DC refrigerators]] and induction cooktops can run off of both 12v or 24v, and are slightly more efficient when running off of 24v
 +      * [[hvac:solar_ac|Off-grid Air Conditioning]] can be slightly more efficient with 24v native systems, and will allow smaller wires to be used.
     * You have a lot of long, large cable runs     * You have a lot of long, large cable runs
       * 24v doesn't have as much voltage drop as 12v over a similar distance, and can use smaller/cheaper cables.       * 24v doesn't have as much voltage drop as 12v over a similar distance, and can use smaller/cheaper cables.
Line 159: Line 160:
 ===== solar panel array ===== ===== solar panel array =====
  
-Pick a solar panel array output on battery bank capacity.  A common **rule of thumb for matching panels to battery bank** is that there should be **at least** 1 panel watt per amp-hour of nominal bank capacity.  +Pick a solar panel array output on daily power requirements and  battery bank capacity.  A common **rule of thumb for matching panels to battery bank** is that //at a minimum// there should be 1 panel watt per amp-hour of nominal bank capacity.  
  
 > "...the person draining their batteries to the 50% range regularly would do much better with a 2 watts to 1Ah ratio, or even 3 to 1." -- SternWake((http://www.cheaprvliving.com/forums/Thread-How-much-solar-do-I-need?pid=278438#pid278438)) > "...the person draining their batteries to the 50% range regularly would do much better with a 2 watts to 1Ah ratio, or even 3 to 1." -- SternWake((http://www.cheaprvliving.com/forums/Thread-How-much-solar-do-I-need?pid=278438#pid278438))