 ====== Slim battery reserves ====== ====== Slim battery reserves ======
 +
 +FIXME:  edit/organize
  
 Note:  this section is likely not appropriate for newbies;  if the ideas are implemented incorrectly it could result in [[electrical:batterycide|battery murder]] and disappointment. Note:  this section is likely not appropriate for newbies;  if the ideas are implemented incorrectly it could result in [[electrical:batterycide|battery murder]] and disappointment.
Line 8: Line 10:
 [[electrical:solar:sizing#your_reserve_needs|Days of reserve calculations]] usually assume //poor solar harvest// == //zero solar harvest// In reality this is almost always incorrect;  //some// solar power is harvested even under dark overcast or rainy conditions. [[electrical:solar:sizing#your_reserve_needs|Days of reserve calculations]] usually assume //poor solar harvest// == //zero solar harvest// In reality this is almost always incorrect;  //some// solar power is harvested even under dark overcast or rainy conditions.
  
-> In light-colored full overcast I see yields 25% of usual.  In dark full overcast, as when storming, I see yields 10% of usual. -- secessus+> In normal full overcast I see yields 20% of usual.  In dark full overcast, as when storming, I see yields 5-10% of usual. -- secessus 
 + 
 +A **fractional reserve** might be a half- or quarter day of battery reserve.  This takes into account the (reduced) contributions from your solar, alternator, etc.  It may also require going into voluntary [[electrical:solar:rationing|power-rationing mode]] when solar output is very low.
  
 +In areas with abundant and consistent [[electrical:solar:output|insolation]] like the desert southwest, you may be able to run with no reserves at all, just enough make it through the night.
 +===== techniques =====
  
-===== fractional reserves =====+making more power
  
-A fractional reserve might be a half- or quarter day of battery reserve.  This takes into account the (reducedcontributions from your solar, alternator, etc.  It may also require going into voluntary [[electrical:solar:rationing|power-rationing mode]] when solar output is very low.+  * [[electrical:solar:overpaneling|Overpaneling]] (having extra panelsis a key technique 
 +  * addimg [[electrical:12v:alternator|alternator]] or other forms of [[electrical:12v:alt_and_solar|additional charging]].
  
-[[electrical:solar:overpaneling|Overpaneling]] [[electrical:solar:ratio|2:1]] or so will help gather more solar energy when running slim reserves.+using less power
  
 +  * Time-shifting loads to [[electrical:solar:nonessential|periods of excess power]] will help keep the solar fully-utilized and bank fully charged until the sun goes down.
 +  * finding and disabling [[electrical:12v:loads|parasitic loads]]  
  
  
-===== zero reserves ===== 
  
  