electrical:solar:status [2017/12/02 04:44]
frater_secessus
electrical:solar:status [2018/05/19 08:20]
frater_secessus [Is my solar working?]
Line 9: Line 9:
   - solar is $$$; and   - solar is $$$; and
   - solar can seem magical; and   - solar can seem magical; and
-  - **both poorly running systems and mostly/fully charged systems show low levels of output**+  - both **poorly running systems** and **mostly/fully charged systems** show low levels of output for different reasons
  
 The last point may be counterintuitive.  A **fully charged system** is observed to deliver very little power because the bank is already charged;  the system is loafing, waiting for a load.  It only cranks up power when you add a big load or start charging a depleted battery.  With lead chemistry batteries this also applies in [[electrical:12v:charging#absorption_stage|Absorption stage]], when the battery reduces the amount of current it will accept. The last point may be counterintuitive.  A **fully charged system** is observed to deliver very little power because the bank is already charged;  the system is loafing, waiting for a load.  It only cranks up power when you add a big load or start charging a depleted battery.  With lead chemistry batteries this also applies in [[electrical:12v:charging#absorption_stage|Absorption stage]], when the battery reduces the amount of current it will accept.