Line 81: Line 81:
   * Vbatt == Vabs until the controller's criteria for ending absorption is met   * Vbatt == Vabs until the controller's criteria for ending absorption is met
   * Controller output decreasing as current demand drops.   * Controller output decreasing as current demand drops.
-  * **Example:**  Panel voltage 17v and rising, battery voltage held at Vabs == 12.6v, controller output amps 2A and dropping+  * **Example:**  Panel voltage 17v and rising, battery voltage held at Vabs == 14.6v, controller output amps 2A and dropping
  
 **During Absorption charging with PWM** **During Absorption charging with PWM**
Line 87: Line 87:
   * Controller output decreasing as current demand drops.   * Controller output decreasing as current demand drops.
   * the controller may get warmer as current demand drops((percentage of time the PWM circuit is turned OFF increases))   * the controller may get warmer as current demand drops((percentage of time the PWM circuit is turned OFF increases))
-  * **Example:**  Panel and battery voltage held at Vabs == 12.6v, controller output 2A and dropping+  * **Example:**  Panel and battery voltage held at Vabs == 14.6v, controller output 2A and dropping
  
 ==== in float ==== ==== in float ====