-This page is to help solar beginners tell what their system is doing without special equipment.  +This page is to help solar beginners tell what their system is doing without special equipment.  The info here is oriented to typical 12v systems with lead-acid battery banks.  Folks running other battery chemistries or nominal voltages are assumed to already know what they're doing.  :-)
  
 ===== numbers rather than icons or lights ===== ===== numbers rather than icons or lights =====
Line 64: Line 64:
  
 **During bulk charging with MPPT** **During bulk charging with MPPT**
-  * Vpanel == Vmp+  * Vpanel == Vmp((although [[electrical:solar:output|temperature derating]] will cause Vmp to drop))
   * Vbatt climbing toward Vabs   * Vbatt climbing toward Vabs
-  * Current delivered to battery holds steady+  * Current delivered to battery holds steady((assuming sunlight holds steady))
   * **Example:**  Panel voltage at Vmp == 17v, battery voltage 12.9v and rising, controller output steady at 4A.   * **Example:**  Panel voltage at Vmp == 17v, battery voltage 12.9v and rising, controller output steady at 4A.
  