   * the controller may get warmer as current demand drops((percentage of time the PWM circuit is turned OFF increases))   * the controller may get warmer as current demand drops((percentage of time the PWM circuit is turned OFF increases))
   * **Example:**  Panel and battery voltage held at Vabs == 14.6v, controller output 2A and dropping   * **Example:**  Panel and battery voltage held at Vabs == 14.6v, controller output 2A and dropping
 +
 +==== transitioning to float ====
 +
 +When transitioning from Absorption to Float the voltage needs to drop about a volt.  The system will "free-fall" (make little or no power) to allow the voltage to fall.  The transition may take seconds or minutes, depending on how/if the system is loaded.
 +
 +  * starts at Vabs
 +  * power generation stops
 +  * voltage drops to Vfloat
 +  * when voltage reaches Vfloat the system will start making power to hold that setpoint.
 +
  
 ==== in float ==== ==== in float ====