User Tools

Site Tools


electrical:solar:status

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
electrical:solar:status [2023/09/02 12:48]
frater_secessus [panel specs]
electrical:solar:status [2024/01/14 10:46]
frater_secessus [setups with no float] link to float to make things easier
Line 124: Line 124:
 ==== setups with no float ==== ==== setups with no float ====
  
-Configurations with no float ("charge and stop", found on some Lithium profiles) will stop charging then fall all the way to the reBulk/reBoost setpoint.  At that point they begin charging again.  +Configurations with no float ("charge and stop", found on some Lithium profiles) will  
 + 
 +  - charge to the Absorption ("boost") setpoint((with or without some amount of Absorption duration)) 
 +  - **stop charging** 
 +  - until voltage falls to the rebulk ("reboost", "boost return voltage") setpoint 
 +  - repeat 
 + 
 +The fall to reBulk looks like the transition to Vfloat [[electrical:solar:status#transitioning_to_float|described above]]. In both cases the controller makes no (or practically no) power until the lower setpoint is reached 
 + 
 +=== Renogy confusion === 
 + 
 +By default Renogy Li profiles work this way, and cause much concern for Renogy users who have not read their manuals and/or who are not familiar with how solar charge controllers / chargers work. [The required information is present [[https://www.renogy.com/support/downloads|in the manuals]] but Renogy really should spell it out for first-timers. -- secessus] 
 + 
 +  * **Rover series** - the table on page 37 of [[https://www.renogy.com/content/RNG-CTRL-RVR40/RVR203040-Manual.pdf|the manual]] shows there is no boost duration and no float in the Li profile.  The "boost return voltage" field shows **13.2v**.  
 +  * **DC-DC/MPPT combo charger** - the table on page 2 of [[https://www.renogy.com/content/RBC3050D1S-G1/RBC3050D1S-Manual.pdf|the manual]] shows there is no boost duration and no float in the Li profile.  The "boost return voltage" field shows **13.2v**.  
 +  * **DC-DC charger** (20A/40A/60A)  
 +    * page 18 says "lithium batteries will only have an absorption charge and no float charge" 
 +    * there is no setting for Float charge, as shown in the table on page 17 of [[https://www.renogy.com/content/RNG-DCC1212-60-BC/DCC1212-204060-Manual.pdf|the manual]] and it says "for lithium... there will not be a float voltage" 
 +    * page 18 says that Float is for lead only 
 +    * the manual does not state the 13.2v boost return setpoint [an egregious error - secessus] 
 + 
 +Users uncomfortable with this behavior can set up the USER profile to meet their needs, including defining [[electrical:12v:drop-in_lifepo4#mythyou_shouldn_t_float_lithium|a quasi-Float setpoint]].((low temp charging cutoff, when available, may only be available in canned Li profiles)) 
  
-The fall to reBulk looks like the transition to Vfloat described above. In both cases the controller makes no (or practically no) power until the lower setpoint is reached.  
 ==== in float ==== ==== in float ====
  
electrical/solar/status.txt · Last modified: 2024/01/14 15:32 by frater_secessus