electrical:solar:status [2023/11/19 17:15]
frater_secessus [setups with no float]
electrical:solar:status [2024/01/14 10:46]
frater_secessus [setups with no float] link to float to make things easier
Line 126: Line 126:
 Configurations with no float ("charge and stop", found on some Lithium profiles) will  Configurations with no float ("charge and stop", found on some Lithium profiles) will 
  
-  - charge to the Absorption ("boost") setpoint+  - charge to the Absorption ("boost") setpoint((with or without some amount of Absorption duration))
   - **stop charging**   - **stop charging**
   - until voltage falls to the rebulk ("reboost", "boost return voltage") setpoint   - until voltage falls to the rebulk ("reboost", "boost return voltage") setpoint
   - repeat   - repeat
  
-The fall to reBulk looks like the transition to Vfloat described above. In both cases the controller makes no (or practically no) power until the lower setpoint is reached. +The fall to reBulk looks like the transition to Vfloat [[electrical:solar:status#transitioning_to_float|described above]]. In both cases the controller makes no (or practically no) power until the lower setpoint is reached. 
  
 === Renogy confusion === === Renogy confusion ===
Line 145: Line 145:
     * the manual does not state the 13.2v boost return setpoint [an egregious error - secessus]     * the manual does not state the 13.2v boost return setpoint [an egregious error - secessus]
  
-Users uncomfortable with this behavior can set up the USER profile to meet their needs, including defining [[electrical:12v:drop-in_lifepo4#mythyou_shouldn_t_float_lithium|a quasi-Float setpoint]]. +Users uncomfortable with this behavior can set up the USER profile to meet their needs, including defining [[electrical:12v:drop-in_lifepo4#mythyou_shouldn_t_float_lithium|a quasi-Float setpoint]].((low temp charging cutoff, when available, may only be available in canned Li profiles))
  
  
electrical/solar/status.txt ยท Last modified: 2024/01/14 15:32 by frater_secessus