Differences
This shows you the differences between two versions of the page.
Both sides previous revision
Previous revision
|
Next revision
Both sides next revision
|
electrical:solar:tracer [2018/06/16 22:40] frater_secessus [quirks] |
electrical:solar:tracer [2018/06/16 22:41] frater_secessus [quirks] |
Tracer (and the Renogy rebrands) refer to the **Absorption stage as "boost"**. This is an unforced error; the nonstandard term confuses newcomers and conflicts with the already-existing "[[electrical:solar:charge_controller#mppt|MPPT boost]]" term. | Tracer (and the Renogy rebrands) refer to the **Absorption stage as "boost"**. This is an unforced error; the nonstandard term confuses newcomers and conflicts with the already-existing "[[electrical:solar:charge_controller#mppt|MPPT boost]]" term. |
| |
The **battery icon** found on many Tracer controllers is unnecessary and misleading. The manual claims it is a [[electrical:depth_of_discharge|State of Charge]] meter but there is no guide to reading it. Since the same voltage can result in different display during charging and non-charging scearios, it may actually be a **charging indicator rather than state of charge indicator**. Secessus' unscientific observation reveals these weak correlations: | The **battery icon** found on many Tracer controllers is unnecessary and misleading. The manual claims it is a [[electrical:depth_of_discharge|State of Charge]] meter but there is no guide to reading it. Since the same voltage can result in different display during charging and non-charging scenarios, it may actually be useful to think of as a **charging indicator rather than state of charge indicator**. Secessus' unscientific observation reveals these weak correlations: |
| |
| | **Charging**| **Not charging**| | | | **Charging**| **Not charging**| |