Differences
This shows you the differences between two versions of the page.
Both sides previous revision
Previous revision
Next revision
|
Previous revision
Next revision
Both sides next revision
|
food:refrigeration [2021/10/14 12:26] frater_secessus [Peltier refrigeration] |
food:refrigeration [2022/01/14 20:52] princess_fluffypants [compressor refrigeration] |
* [[https://amzn.to/3xjrrJt|Iceco VL45]] recommended by doc-ketamine((https://www.reddit.com/r/overlanding/comments/o8orti/newbie_question_on_jackery_bluetti_portable_power/h37nb5r/)). Measured 85w when compressor is running | * [[https://amzn.to/3xjrrJt|Iceco VL45]] recommended by doc-ketamine((https://www.reddit.com/r/overlanding/comments/o8orti/newbie_question_on_jackery_bluetti_portable_power/h37nb5r/)). Measured 85w when compressor is running |
* [[https://amzn.to/3jHCrwp|Iceco JP50]] recommended by panchulio.((https://www.reddit.com/r/overlanding/comments/o8orti/newbie_question_on_jackery_bluetti_portable_power/h36aiad/)) | * [[https://amzn.to/3jHCrwp|Iceco JP50]] recommended by panchulio.((https://www.reddit.com/r/overlanding/comments/o8orti/newbie_question_on_jackery_bluetti_portable_power/h36aiad/)) |
| * [[https://icecofreezer.com/collections/iceco-vl-series/products/iceco-vl60-dual-zone-portable-refrigerator-freezer|IceCo Dual Zone Series]] is great for people who want capable freezer space |
| |
| |
==== Peltier refrigeration ==== | ==== Peltier refrigeration ==== |
| |
Peltier cooling doesn't get used much in solar setups because it uses a lot of power and does so 100% of the time. A typical Peltier cooler might run 4-5A continuously whereas a compressor cooler might run 2A 30% of the time and turn off the rest of the time. The 100% duty cycle issue can be alleviated by wiring in [[https://amzn.to/2WJg4tu|a 12v thermostat]].((assuming it would ever get cold enough to shut off. )) | Peltier cooling doesn't get used much in solar setups because it uses a lot of power and does so 100% of the time. A typical Peltier cooler might run 4-5A continuously whereas a compressor cooler might run 5A 30% of the time and turn off the rest of the time. The 100% duty cycle issue can be alleviated by wiring in [[https://amzn.to/2WJg4tu|a 12v thermostat]].((assuming it would ever get cold enough to shut off. )) |
| |
This kind of device cools to ~30-40F below ambient, which may not be a problem if the ambient is 80F or less. For best results avoid putting hot or even warmer-than-ambient items in the cooler. Use a fan on the item until it is room temp before placing in cooler. | This kind of device cools to ~30-40F below ambient, which may not be a problem if the ambient is 80F or less. For best results avoid putting hot or even warmer-than-ambient items in the cooler. Use a fan on the item until it is room temp before placing in cooler. |