   * **A** - Amps (amperes).  A measure of electrical current.   * **A** - Amps (amperes).  A measure of electrical current.
-  * **AH** or **Ah** - Amp-hour+  * **AH** or **Ah** - Amp-hour.  Example:  2.5A x 2 hours = 5Ah.   
 +    * Note that Ah is voltage-dependent:  5Ah at 12v is 60Wh, while 5A at 24v = 120Wh.  For this reason, Wh may be a more "portable" specification.  
 +    * the [[electrical:12v:battery_capacity|capacity]] of [[electrical:12v:deep_cycle_battery|deep cycle]] batteries is traditionally given in Ah.  Example:  a 100Ah battery will provide 100Ah from 100% to 0% DoD at a ~5A draw (C/20).
   * **AGM** [[electrical:12v:deep_cycle_battery#agm|Absorbent Glass Mat]] battery, a type of [[electrical:12v:deep_cycle_battery#vrla|Valve Regulated Lead Acid battery]]   * **AGM** [[electrical:12v:deep_cycle_battery#agm|Absorbent Glass Mat]] battery, a type of [[electrical:12v:deep_cycle_battery#vrla|Valve Regulated Lead Acid battery]]
  
Line 31: Line 33:
 ===== G ===== ===== G =====
   * **GC** - [[electrical:12v:deep_cycle_battery|6v golf cart battery]]   * **GC** - [[electrical:12v:deep_cycle_battery|6v golf cart battery]]
 +  * **GVWR** - Gross Vehicle Weight Rating: maximum weight the vehicle can carry 
 +  * **GCWR** - Gross Combined Weight Rating: maximum towable weight 
 +  * **GAWR** - Gross Axle Weight Rating: maximum weight each axle can carry
 ===== I ===== ===== I =====
    
Line 42: Line 46:
   * **MPPT** - Maximum Power Point Tracking, a type of [[electrical:solar:charge_controller|charge controller]]     * **MPPT** - Maximum Power Point Tracking, a type of [[electrical:solar:charge_controller|charge controller]]  
  
 +===== N =====
 +
 +  * **normally closed** (NC) - a relay where the unpowered (default) condition is //closed//, i.e. relayed circuit is complete and electricity can flow
 +  * **normally open** (NO) - a relay where the unpowered (default) condition is //open//, i.e. relayed circuit is broken and electricity cannot flow
 ===== P ===== ===== P =====
   * **Pmax** - **max**imum **p**ower the panel can output   * **Pmax** - **max**imum **p**ower the panel can output