Previous revision
opinion:frater_secessus:lifepo4_charging_voltage [2023/06/28 23:32]
frater_secessus [the full process]
opinion:frater_secessus:lifepo4_charging_voltage [2024/02/10 11:33] (current)
frater_secessus [the full process13.6v example
Line 1: Line 1:
 DRAFT DRAFT
  
-====== Problems caused by excessive LiFePO4 charging voltage ======+====== Problems caused by lithium charging profiles ====== 
 + 
 +You'd think that a "lithium profile" would be suitable for lithium.  That may or may not be so for your particular use case.  Read on... 
 +===== excessive charging voltage =====
    
 [[https://img.mousetrap.net/misc/toohigh.jpg|{{ https://img.mousetrap.net/misc/thumbs/toohigh.jpg}}]] [[https://img.mousetrap.net/misc/toohigh.jpg|{{ https://img.mousetrap.net/misc/thumbs/toohigh.jpg}}]]
Line 14: Line 17:
  
  
-===== TLDR =====+==== TLDR ====
  
-If this is the problem then reducing the charging voltage will cause the symptoms to improve or disappear.+If excessive charging voltage is the problem then reducing the charging voltage will cause the symptoms to improve or disappear.
  
 [[opinion:frater_secessus:pareto|about these summaries]] [[opinion:frater_secessus:pareto|about these summaries]]
-===== the full process =====+ 
 +==== the full process ====
  
  
Line 27: Line 31:
   - if it starts acting up again drop charging voltage back down a notch or two   - if it starts acting up again drop charging voltage back down a notch or two
  
-==== why lower-voltage charging works ====+=== why lower-voltage charging works ===
  
  
 LiFePO4 will fully charge at voltages as low as the mid-13s,  but it will take more time.  That extra time is called "Absorption duration"(("boost duration in Renogy- and EpEver-speak)).  At the kinds of current levels we usually see in offgrid charging((~0.2C)) the duration looks like this: LiFePO4 will fully charge at voltages as low as the mid-13s,  but it will take more time.  That extra time is called "Absorption duration"(("boost duration in Renogy- and EpEver-speak)).  At the kinds of current levels we usually see in offgrid charging((~0.2C)) the duration looks like this:
  
-  *  ≥14.0v will charge to 100% SoC with zero minutes of absorption durations: hit the voltage setpoint and //stop//. Cell voltages tend to diverge as charging voltage increases above 14.0v because they are further up the knee (see below)  +  *  ≥14.0v will charge to ~100% SoC with zero minutes of absorption durations: hit the voltage setpoint and //stop//. Cell voltages tend to diverge as charging voltage increases above 14.0v because they are further up the knee (see below)  
-  * 13.8v will charge to 100% SoC with a small amount of Absorption (10-30 minutes?) and cells tend to stay in balance. +  * 13.8v will charge to ~100% SoC with a small amount of Absorption (10-30 minutes?) and cells tend to stay in balance. 
-  * 13.6v will charge to 100% SoC with several hours of Absorption  <-- where we are starting +  * 13.6v will charge to ~100% SoC with several hours of Absorption ([[https://diysolarforum.com/threads/victron-dcdc-12-12-30-charger-no-bluetooth-on-new-install.78373/post-1003471|example]] with data)  <-- where we are starting
-  * 13.4v will //eventually// fully charge the bank but it would take days.  It takes so long we can use 13.4v as a Float voltage.+
  
-   
  
- +==== why the problem occurs ====
- +
- +
- +
- +
- +
- +
-===== why the problem occurs =====+
  
 {{  https://us.v-cdn.net/6024911/uploads/editor/ty/18vvr0fd7cff.jpg?135}} {{  https://us.v-cdn.net/6024911/uploads/editor/ty/18vvr0fd7cff.jpg?135}}
Line 60: Line 55:
  
  
-===== further reading =====+==== further reading ====
  
   * [[electrical:12v:drop-in_lifepo4#why_are_manufacturer-recommended_charging_voltages_so_high|an approach to greater LiFePO4 longevity]]   * [[electrical:12v:drop-in_lifepo4#why_are_manufacturer-recommended_charging_voltages_so_high|an approach to greater LiFePO4 longevity]]
 +
 +
 +===== lack of pseudo-float =====
 +
 +So your charge controller isn't charging even though battery state of charge is dropping?
 +
 +This can be intentional behavior, caused by a Li profile that 
 +
 +  - charges to a high voltage (see above)
 +  - then allows the battery to discharge until it hits the [[electrical:solar:charge_controller_setpoints|Rebulk setpoint]]...
 +  - at which point it charges to the high voltage again...
 +  - rinse and repeat until the sun goes down
 +
 +During the discharge stage the controller will appear to stop working.  In reality it's waiting to hit that rebulk setpoint to start the party again.  
 +
 +To avoid this problem. configure a "float" voltage of 13.3v-13.4v.  [[electrical:12v:drop-in_lifepo4#mythyou_shouldn_t_float_lithium|This will hold state of charge without overcharging]]. 
  
  
opinion/frater_secessus/lifepo4_charging_voltage.1688009546.txt.gz · Last modified: 2023/06/28 23:32 by frater_secessus