opinion:frater_secessus:lifepo4_charging_voltage [2023/08/30 23:40]
frater_secessus [the full process]
opinion:frater_secessus:lifepo4_charging_voltage [2024/02/10 11:33] (current)
frater_secessus [the full process13.6v example
Line 38: Line 38:
   *  ≥14.0v will charge to ~100% SoC with zero minutes of absorption durations: hit the voltage setpoint and //stop//. Cell voltages tend to diverge as charging voltage increases above 14.0v because they are further up the knee (see below)    *  ≥14.0v will charge to ~100% SoC with zero minutes of absorption durations: hit the voltage setpoint and //stop//. Cell voltages tend to diverge as charging voltage increases above 14.0v because they are further up the knee (see below) 
   * 13.8v will charge to ~100% SoC with a small amount of Absorption (10-30 minutes?) and cells tend to stay in balance.   * 13.8v will charge to ~100% SoC with a small amount of Absorption (10-30 minutes?) and cells tend to stay in balance.
-  * 13.6v will charge to ~100% SoC with several hours of Absorption  <-- where we are starting+  * 13.6v will charge to ~100% SoC with several hours of Absorption ([[https://diysolarforum.com/threads/victron-dcdc-12-12-30-charger-no-bluetooth-on-new-install.78373/post-1003471|example]] with data)  <-- where we are starting
  
  