User Tools

Site Tools


opinion:frater_secessus:panelsizesforinsolation

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
opinion:frater_secessus:panelsizesforinsolation [2022/07/20 16:40]
frater_secessus [Amount of solar wattage required per 100Ah of Pb] further reading
opinion:frater_secessus:panelsizesforinsolation [2024/03/20 00:01] (current)
frater_secessus [Amount of solar wattage required per 100Ah of Pb]
Line 41: Line 41:
 These are crude estimates about the panel wattage required to fully charge 100Ah of AGM from 50% DoD each day.  See the list of assumptions below the chart.   These are crude estimates about the panel wattage required to fully charge 100Ah of AGM from 50% DoD each day.  See the list of assumptions below the chart.  
  
-^ Location       ^ [[electrical:solar:charge_controller#mppt|MPPT]] only  ^ [[electrical:solar:charge_controller#pwm|PWM]] only  ^ w/ [[electrical:12v:alternator|isolator]]  ^ w/ [[electrical:12v:b2b|DC-DC charger]] or [[electrical:generator|generator]]  ^+^ Location       ^ [[electrical:solar:charge_controller#mppt|MPPT]] only  ^ [[electrical:solar:charge_controller#pwm|PWM]] only  ^ w/ [[electrical:12v:alternator|"isolator"]]  ^ w/ [[electrical:12v:b2b|DC-DC charger]] or [[electrical:generator|generator]]  ^
 | Seattle - avg  | 280w                                                   | 329w                                                 | 140w                                       | 103w                                                                           | | Seattle - avg  | 280w                                                   | 329w                                                 | 140w                                       | 103w                                                                           |
 | Seattle - Dec  | 921w                                                   | 1056w                                                | 528w                                       | 388w                                                                           | | Seattle - Dec  | 921w                                                   | 1056w                                                | 528w                                       | 388w                                                                           |