- up to its abilities under present conditions | - up to its abilities under present conditions | ||
- | So why does it not make power sometimes? | + | In most cases the system is working as designed but the owner doesn' |
Line 17: | Line 17: | ||
+ | ==== charge-and-stop ==== | ||
+ | Charge-and-stop usually charges to 14.2v or 14.4v then stops until nank voltage drops to 13.2v before restarting Bulk charging. This occurs because charge-and-stop does not use a Float setpoint.((Li doesn' | ||
+ | |||
+ | Under very light loads this would result in cycling between 90% and 100% state of charge. | ||
+ | |||
+ | If this is undesirable behavior you can set up a USER profile with whatever setpoints you wish ([[electrical: | ||
===== because the panels aren't receiving full sunlight ===== | ===== because the panels aren't receiving full sunlight ===== | ||
Line 27: | Line 33: | ||
===== because the BMS has shut down charging ===== | ===== because the BMS has shut down charging ===== | ||
- | ...because of temperature extremes of [[opinion: | + | ...because of temperature extremes of [[opinion: |