Line 560: Line 560:
   * LiFePO4 resting voltages are high enough they may hold the circuit closed on VSRs designed for lead chemistries.  Workaround:  [[electrical:12v:alternator#disabling_alternator_charging|disable alternator charging]] (at least momentarily) after driving or install DC-DC.  Or just let it work that way.     * LiFePO4 resting voltages are high enough they may hold the circuit closed on VSRs designed for lead chemistries.  Workaround:  [[electrical:12v:alternator#disabling_alternator_charging|disable alternator charging]] (at least momentarily) after driving or install DC-DC.  Or just let it work that way.  
   * Voltage-sensing relays can be unintentionally triggered((dVSR)) or "held closed"((both VSR and dVSR)) [[http://bdp.mousetrap.net/index.php/2018/10/27/side-effect-of-solar-alternator-charging/|by voltage from the solar-charged side]] in some scenarios.   Workaround:  address with HVD as below if desired, or with a [[electrical:12v:b2b|DC-DC charger]], or by adding a switch to disable the VSR.((a momentary-off switch would kill the connection, although an ON/OFF switch might be useful for other purposes))    * Voltage-sensing relays can be unintentionally triggered((dVSR)) or "held closed"((both VSR and dVSR)) [[http://bdp.mousetrap.net/index.php/2018/10/27/side-effect-of-solar-alternator-charging/|by voltage from the solar-charged side]] in some scenarios.   Workaround:  address with HVD as below if desired, or with a [[electrical:12v:b2b|DC-DC charger]], or by adding a switch to disable the VSR.((a momentary-off switch would kill the connection, although an ON/OFF switch might be useful for other purposes)) 
-  * On ignition-triggered((IGN, D+)) setups if the key is turned to ACC but the engine not started a depleted house battery can pull down the starter battery**.  Workarounds:  use a VSR, a DC delay timer, a DC-DC charger, or start the vehicle immediately after inserting the key((ie, do not leave in the Accessory position which would drain the starter battery)).  +  * On ignition-triggered((IGN, D+)) setups **if the key is turned to ACC but the engine not started a depleted house battery can pull down the starter battery**.  Workarounds:  use a VSR, a DC delay timer, a DC-DC charger, or start the vehicle immediately after inserting the key((ie, do not leave in the Accessory position which would drain the starter battery)).  
   * Solar charging while the engine is running may [[opinion:frater_secessus:alternatorSolarStall|get "stuck" at alternator voltage]].  Workaround:  higher solar wattage, DC-DC charger, or diode/FET-based isolator, or a switch to disconnect isolator after alternator voltage is reached.  The [[https://amzn.to/3h5iMUd|Victron Cyrix-ct isolator]] could be useful here, as it appears to disconnect >13.8v.((https://www.victronenergy.com/upload/documents/Datasheet-Cyrix-ct-120A-230A-EN.pdf))   * Solar charging while the engine is running may [[opinion:frater_secessus:alternatorSolarStall|get "stuck" at alternator voltage]].  Workaround:  higher solar wattage, DC-DC charger, or diode/FET-based isolator, or a switch to disconnect isolator after alternator voltage is reached.  The [[https://amzn.to/3h5iMUd|Victron Cyrix-ct isolator]] could be useful here, as it appears to disconnect >13.8v.((https://www.victronenergy.com/upload/documents/Datasheet-Cyrix-ct-120A-230A-EN.pdf))
-  * Alternator charging may bring some battery chemistries (like bare lithium cells with no BMS) to **unsuitably high voltages**.  Workarounds:  A [[electrical:12v:hvd|high voltage disconnect]] can [[electrical:12v:alternator charging hvd|restrict alternator charging to lower voltages]].  [[electrical:12v:b2b|DC-DC chargers]] can also regulate voltage provided to the house battery.  +  * Alternator charging may bring some battery chemistries (like bare lithium cells with no BMS) to **unsuitably high voltages**.  Workarounds:  A [[electrical:12v:hvd|high voltage disconnect]] can [[electrical:12v:alternator charging hvd|restrict alternator charging to lower voltages]]. And [[electrical:12v:b2b|DC-DC chargers]] can also regulate voltage provided to the house battery.  
-  * It is possible for a plain combiner to "mask" the symptoms of a failing starter battery since the house bank would be assisting with the start. +  * It is possible for a plain combiner to "mask" the symptoms of a failing starter battery since the house bank would be assisting with the start. It is also possible for powerful solar to mask symptoms of a dying alternator because in that case the solar is helping run the chassis electricals
  
 ===== disabling alternator charging ===== ===== disabling alternator charging =====