+ | ===== gotchas ===== | ||
+ | |||
+ | Observe voltage input maximums on units with built-in solar charge controllers. | ||
+ | |||
+ | Voltage-sensing units((triggered by elevated chassis voltage)) can misbehave when an undersized starter battery charger/ | ||
+ | |||
+ | - starter battery voltage rises from 10A maintainer charging... | ||
+ | - triggering the DC-DC charger... | ||
+ | - which begins pulling up to 20A from the chassis | ||
+ | - pulling down the starter battery since the 10A maintainer cannot keep up | ||
+ | - starter battery voltage drops far enough the DC-DC turns off | ||
+ | - repeat forever | ||
+ | |||
+ | The workaround is to either charge the house battery first or to buy a big enough starter battery maintainer to support both the starter battery and DC-DC charger loads. | ||