User Tools

Site Tools


electrical:12v:b2b

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
electrical:12v:b2b [2024/04/12 21:52]
frater_secessus [Kisae]
electrical:12v:b2b [2024/05/17 11:40]
frater_secessus [Renogy]
Line 147: Line 147:
  
 === RBC series === === RBC series ===
 +
 +NOTE:  there are two distinct versions of the RBC line.  Both appear to have PV input limits higher than 25v found in the older DCC line.  Major differences appear to be:
 +
 +  * DS - built-in Bluetooth, support for both 12v/24v banks.  New case.
 +  * D1S -  no built-in Bluetooth, 12v banks only.  Uses traditional DCC case.
 +
 +
 +== RBC2125DS ==
 +
 +
 +{{ https://cdn11.bigcommerce.com/s-fhnch/images/stencil/640w/products/2063/26190/1__10088.1706872952.jpg?125}}
  
 Note:  some manual versions brand this unit as part of the "Rego" line. Note:  some manual versions brand this unit as part of the "Rego" line.
  
-The [[https://www.renogy.com/renogy-12v-24v-ip67-50a-dc-dc-battery-charger-with-mppt/|RBC series 50A charger]] has a 50V PV input limit and built-in bluetooth.  It can also boost 12v panel voltage to charge 24v banks.  A RBC30 is reported to exist.+This version is for both **12v and 24v banks**.
  
-The existing [[https://store-fhnch.mybigcommerce.com/content/RBC2125DS-21W/Manual_RENOGY%2012V%2024V%2050A%20Battery%20Charger-2.pdf|manual]] is minimal and specs/behavior are largely undocumented as of Jan 2024.+The [[https://www.renogy.com/renogy-12v-24v-ip67-50a-dc-dc-battery-charger-with-mppt/|RBC series 50A charger]] has a 50V PV input limit and built-in bluetooth.  It can also boost 12v panel voltage to charge 24v banks 
  
 +>> Ensure that the open circuit voltage of the solar panel/solar panel array does not exceed 50V
 +
 +Update:  [[https://store-fhnch.mybigcommerce.com/content/RBC2125DS-21W/Manual_RENOGY%2012V%2024V%2050A%20Battery%20Charger-2.pdf|the manual]] has been updated.
  
 == solar+alternator behavior == == solar+alternator behavior ==
Line 163: Line 177:
  
  
 +== RBC30D1S and RBC50D1S ==
 +
 +The D**1**S series appears to be a DCC charger with higher PV input limits: 
 +
 +>> For [the] 30A battery charger, ensure that the working voltage of the solar panel / solar panel array does not exceed **30V**. For [the] 50A battery charger, ensure that the working voltage of the
 +solar panel / solar panel array does not exceed **50V**.
  
 +[[https://www.renogy.com/content/RBC3050D1S-G1/RBC3050D1S-Manual.pdf|manual]]
  
  
electrical/12v/b2b.txt ยท Last modified: 2024/06/02 20:28 by frater_secessus