electrical:12v:voltage_sag [2022/03/16 13:38] frater_secessus [Voltage sag] |
electrical:12v:voltage_sag [2022/03/16 13:39] frater_secessus [shorten the circuit] |
||
---|---|---|---|
Line 16: | Line 16: | ||
This is the majority position since most are unaware of the issue, or don't judge it to be important. | This is the majority position since most are unaware of the issue, or don't judge it to be important. | ||
- | - solar-only charging is often low-current charging, minimizing sag | + | - solar-only charging is often low-current charging, minimizing |
- lead-chemistry batteries often have a range of Absorption and Float [[electrical: | - lead-chemistry batteries often have a range of Absorption and Float [[electrical: | ||
Line 22: | Line 22: | ||
==== shorten the circuit ==== | ==== shorten the circuit ==== | ||
- | A shorter wiring run will have less sag than a longer run. For this reason charging sources are mounted **as close to the battery bank as possible**. | + | All other things being equal, a **shorter wiring run will have less sag** than a longer run. For this reason charging sources are mounted **as close to the battery bank as possible**. |
+ | |||