+ | ==== choosing a converter ==== | ||
+ | If money is no object you can buy a multistage (" | ||
+ | * [[electrical: | ||
+ | * 0.2C for FLA | ||
+ | * 0.4C is not LiFeP)4' | ||
+ | |||
+ | |||
+ | === cost === | ||
+ | |||
+ | |||
+ | The higher the rating and the more features the more expensive the shore power charger. | ||
+ | |||
+ | === limits of 15A shore power === | ||
+ | |||
+ | I would limit myself to 13A off a 15A shore power plug, or 1,560w. Assuming 10% conversion losses this would give us a **theoretical max of around 100A of converter charging** (14.4Vabs x 100A). | ||
+ | |||
+ | |||
+ | === minimum | ||
+ | |||
+ | |||
+ | Lead chemistries require a minimum charge rate to stay healthy, and AGM more than the other lead variants. | ||
+ | |||
+ | * 78A for a 390Ah bank (0.2 x 390Ah). | ||
+ | * 39A for a 195Ah half bank, so a 40A converter | ||
+ | |||
+ | |||
+ | === charging time available === | ||
+ | |||
+ | |||
+ | If you have solar and will be on shore power for more than one day then a simple converter that charges at the batteries' | ||
+ | |||
+ | If you do not have solar or will be on shore power for only one overnight then we need a three-stage (" | ||