This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:generator [2022/01/15 11:35] frater_secessus [efficient use] |
electrical:generator [2023/09/23 13:00] frater_secessus [inverter generators] cleaned up |
||
---|---|---|---|
Line 15: | Line 15: | ||
===== inverter generators ===== | ===== inverter generators ===== | ||
- | Inverter generators adjust engine output to meet power demand. | + | Standard generators run the engine at a specific speed to output stable power. |
+ | |||
+ | [[https:// | ||
+ | |||
+ | As a result | ||
===== etiquette ===== | ===== etiquette ===== | ||
Line 29: | Line 33: | ||
Generators //are// well suited to charging [[electrical: | Generators //are// well suited to charging [[electrical: | ||
+ | |||
+ | If you are considering a genny for use with an inverter/ | ||
+ | |||
+ | > Inverter chargers generally prefer conventional generator and not inverter generators. This is because they control the amount of power they pull from the generator just adjusting your island frequency. Inverter generators do not handle an external actor trying to adjust the frequency and will rigidly keep 50 or 60Hz until they trip. -- therealrimwarren((https:// | ||
===== efficient use ===== | ===== efficient use ===== | ||
Generators generally have a minimum amount of wattage they can produce. | Generators generally have a minimum amount of wattage they can produce. |