* **12v/ | * **12v/ | ||
* **Maximum input voltage** - the highest voltage the controller should //ever// see from the solar array.((it is common to leave ~20% margin)) | * **Maximum input voltage** - the highest voltage the controller should //ever// see from the solar array.((it is common to leave ~20% margin)) | ||
+ | * **Minimum input voltage** - a PWM controller will requires panel voltage ≥ battery voltage to charge. | ||
Line 197: | Line 197: | ||
**MPPT is effectively required** when: | **MPPT is effectively required** when: | ||
* when one needs to squeeze every watt out of the panel | * when one needs to squeeze every watt out of the panel | ||
- | * using panels with nominal voltages higher than the battery bank voltage, like 24v panels with a 12v bank. To be fair, [[http:// | + | * using panels with nominal voltages higher than the battery bank voltage, like 24v panels with a 12v bank. To be fair, [[http:// |
* space available for panels is limited, as on a sailboat or small vehicle | * space available for panels is limited, as on a sailboat or small vehicle | ||