 +==== sensors ====
 +
 +To charge correctly the controller needs to know the precise voltage and temperature of the battery bank.  
 +In the best case scenario these measurements are done with an external **temp sensor** and **voltage sense**((not a typo, it's called voltage sense)) that plug into the controller or talk to the controller via bluetooth. 
 +
 +In the absence of external sensors the controller tries to use any internal sensors it might have.  The values will be inaccurate: 
 +
 +  * battery voltage will read [[electrical:12v:voltage_sag|falsely high during charging]], and
 +  * temperature will read falsely high because of the heat the controller generates from its own electronics
 +
 +With **lead-chemistry batteries** both conditions can cause [[electrical:12v:psoc|chronic undercharging]], a key cause of [[electrical:batterycide|premature battery failure]].  Many **LiFePO4 batteries** have their own [[opinion:frater_secessus:agm2lifepo4#wait_lfp_can_be_damaged_by_charging_in_cold_weather|low temperature charging cutoff]] but those that do not must rely on the charger to disconnect when battery temps are ~freezing.
 +
 +
 +
 +