electrical:solar:charge_controller [2024/06/01 21:57] frater_secessus [specs] |
electrical:solar:charge_controller [2024/06/01 21:58] frater_secessus [sensors] |
* temperature will read high because of the controller's own heat from electronics | * temperature will read high because of the controller's own heat from electronics |
| |
With lead-chemistry batteries both conditions cause [[electrical:12v:psoc|chronic undercharging]], a key cause of [[electrical:batterycide|premature battery failure]]. Many LiFePO4 batteries have [[opinion:frater_secessus:agm2lifepo4#wait_lfp_can_be_damaged_by_charging_in_cold_weather|low temperature charging cutoff]] if the charger cannot disconnect when battery temps are ~freezing. | With lead-chemistry batteries both conditions cause [[electrical:12v:psoc|chronic undercharging]], a key cause of [[electrical:batterycide|premature battery failure]]. Many LiFePO4 batteries have [[opinion:frater_secessus:agm2lifepo4#wait_lfp_can_be_damaged_by_charging_in_cold_weather|low temperature charging cutoff]] but those that do not must rely on the charger to disconnect when battery temps are ~freezing. |
| |
| |