electrical:solar:charge_controller [2024/06/01 21:57]
frater_secessus [specs]
electrical:solar:charge_controller [2024/07/01 22:22]
frater_secessus [sizing your charge controller]
Line 33: Line 33:
  
   * battery voltage will read [[electrical:12v:voltage_sag|falsely high during charging]], and   * battery voltage will read [[electrical:12v:voltage_sag|falsely high during charging]], and
-  * temperature will read high because of the controller's own heat from electronics+  * temperature will read falsely high because of the heat the controller generates from its own electronics
  
-With lead-chemistry batteries both conditions cause [[electrical:12v:psoc|chronic undercharging]], a key cause of [[electrical:batterycide|premature battery failure]].  Many LiFePO4 batteries have [[opinion:frater_secessus:agm2lifepo4#wait_lfp_can_be_damaged_by_charging_in_cold_weather|low temperature charging cutoff]] if the charger cannot disconnect when battery temps are ~freezing.+With **lead-chemistry batteries** both conditions can cause [[electrical:12v:psoc|chronic undercharging]], a key cause of [[electrical:batterycide|premature battery failure]].  Many **LiFePO4 batteries** have their own [[opinion:frater_secessus:agm2lifepo4#wait_lfp_can_be_damaged_by_charging_in_cold_weather|low temperature charging cutoff]] but those that do not must rely on the charger to disconnect when battery temps are ~freezing.
  
  
Line 264: Line 264:
 ===== sizing your charge controller ===== ===== sizing your charge controller =====
 As with [[electrical:inverter|inverters]], sizing the controller correctly will help system efficiency and save money.  An oversized CC will have unnecessarily high parasitic drains as it powers itself and will cost more.  An undersized CC will not be able to put all the rated solar wattage to use and will leave no room for expansion. As with [[electrical:inverter|inverters]], sizing the controller correctly will help system efficiency and save money.  An oversized CC will have unnecessarily high parasitic drains as it powers itself and will cost more.  An undersized CC will not be able to put all the rated solar wattage to use and will leave no room for expansion.
 +
 +
 For PWM controllers, the formula is something like (panel wattage / 13) * (1.2 oversize for safety) = charge controller amps.((https://www.altestore.com/howto/sizing-pwm-solar-charge-controllers-a91/))  For PWM controllers, the formula is something like (panel wattage / 13) * (1.2 oversize for safety) = charge controller amps.((https://www.altestore.com/howto/sizing-pwm-solar-charge-controllers-a91/)) 
 MPPT controllers have more leeway in sizing since they can [[electrical:solar:overpaneling|control the output of the panels]] independently of battery voltage.   MPPT controllers have more leeway in sizing since they can [[electrical:solar:overpaneling|control the output of the panels]] independently of battery voltage.  
electrical/solar/charge_controller.txt ยท Last modified: 2024/07/01 22:48 by frater_secessus